China Cheap price Dry Block Calibration Furnace - ET3805 Intelligent Dry Block Temperature Calibrator Used In Laboratory – Zhongchuang
China Cheap price Dry Block Calibration Furnace - ET3805 Intelligent Dry Block Temperature Calibrator Used In Laboratory – Zhongchuang Detail:
¤ Small size, light weight, easy to carry;
¤ Various types of insertion tubes can meet the test and calibration of sensors of different sizes and quantities. It can also be customized according to customer’s requirement;
¤ Horizontal temperature field and vertical temperature field are good;
¤ Insert depth stays the leading role in this industry
¤ 5.7 inch TFT color LCD display, full touch operation, using intuitive and eye-catching;
¤ Chinese-English interface;
¤ With the management software, the calibration data can be easily read.
¤ Quick cooling, convenient setting, good stability of temperature control;
¤ The soaking block can be replaced;
¤ Protective functions such as short circuit with load, load circuit breaking, sensor protection, etc.
¤ Circuit number and type of electrical measurement signal: 5 channels for electrical measurement, 2 standard channels (one for standard RTD and one for standard thermocouple), 3 channels for multi-function measurement channels ;Multi-function measurement includes: mA/mV/V / Ω measurement, DC24V output HART transmitter (*) , switch measurement, and other functions;
¤ Self-calibration function of temperature parameters (*) : By connecting the external standard thermal resistance to the electrical measurement standard thermal resistance channel, the measurement deviation value of the built-in temperature control sensor can be corrected and the automatic calibration function of temperature parameters of the equipment can be realized.
¤ Support external standard temperature control method (*)
¤ Support one-key self-calibration function of internal temperature sensor (*);
¤ Temperature compensation: automatic (built-in AA Pt100 platinum resistance) or manual;
¤ supports HART type temperature transducer calibration (*);
¤ Automatic verification function (*) : it only needs to set parameters to carry out the automatic verification task of the inspected equipment, automatically calculate the data out-of-tolerance, automatically save the verification results, and support the export and generate records and certificates;
¤ Built-in step test, switch test, temperature control data recording (*), thermal calculator, screen capture, drying dehumidification and other application tools;
¤ Data storage: verify data recording and exporting, support up to 250 sensors, 2500 records;
¤ Communication port: Standard Usb Device, Usb Host, Tcp/IP(LAN), optional Wifi, Bluetooth;
¤ Selected function: temperature verification and calibration system software (can be automatically calibrated, the process and results are in accordance with the calibration specifications;Support field data import;User rights management, instrument management, custom certificate template, automatic generation of records and certificates, etc.
(Note: The function with “*” is an optional function. If you need such functions, please provide the corresponding code when ordering)
① Other temperature ranges should be specified when ordering.
The negative temperature type of -20℃~150℃ has 4 holes,are φ6/ 8/ 10/ 12 mm .The negative temperature type of
-30 ~150 and -40~ 150 has 4 holes,are 6/ 8/ 8/10 mm.
The medium temperature type of has 2 kinds (choose 1 at one time when ordering ), one is 3 holes of 8/ 10/ 12mm, the other is 4 holes of 6mm*2, 8mm*2.
The high temperature type of 300 ~1200 has 4 holes, are 6/ 8/ 10/ 12mm.
The soaking blaock with Special specification could be customized.
index |
Low Temp |
Medium Temp |
High Temp |
|||
ET3805-150A |
ET3805-150B |
ET3805-150C |
ET3805-650 |
ET3805-1200A |
ET3805-1200B |
|
Temp Range ① |
-20℃~150℃ |
-30℃~150℃ |
-45℃~150℃ |
50℃~650℃ |
300~1200℃(A) |
100~1210℃(B) |
Heating Speed |
30~100:20min 30~150:40min |
30~300:7min 30~400:12min 30~650:25min |
30~1200:75min |
|||
Display accuracy |
≤±0.1℃ |
≤400℃:≤±0.35℃ 400-650℃:≤±0.5℃ |
≤±1.2℃ |
|||
Inserted depth |
160mm |
150mm |
135mm |
|||
Diameter of soaking block |
A 36mm,B、C 32mm |
32mm |
39mm |
|||
Stability of temperature field |
≤±0.02℃ |
≤±0.05℃ |
≤±0.2℃ |
|||
Horizontal temperature field |
≤±0.05℃ |
≤±0.05℃ |
≤±0.25℃ |
|||
Vertical temperature field |
≤1℃ within 30mm from bottom of soaking block |
|||||
Temperature unit |
℃ or ℉ |
|||||
Accuracy |
0.1% |
|||||
Resolution rate |
0.1/0.01/0.001℃ |
|||||
Max Power |
Low Temp :300W,Medium Temp :1200W; High Temp:3000W |
|||||
Net Weight |
Low Temp:13kg,Medium Temp:11kg, High Temp:11kg |
|||||
Gross Weight |
Low Temp:23kg ;Medium Temp:18kg High Temp:18kg, including aluminum box and carton box |
|||||
Dimension |
Low Temp:310*190*340mm,Medium Temp:250*150*310mm, High Temp:250*150*310mm |
|||||
Working Environment |
Environment Temp 0~50℃、related humidity ≤95%(no frozen ) |
|||||
Power supply |
220VAC±10%,45~60Hz,or 110VAC±10% |
|||||
Communication port |
Usb Device、Usb Host、Tcp/IP(LAN),optionWifi、bluetooth |
Index |
Low Temperature |
Medium Temperature |
High Temperature |
ET3805-150A/B/C W |
ET3805-650W |
ET3805-1200 A/B W |
|
Channels and Signal types |
5 electric measurement channels,2 standard channels(standard RTD*1,standard thermocouple*1 ) 、3 multifunctional measurement channels |
6 electric measurement channels,2 standard channels(standard RTD*1,standard thermocouple*1 ) 、2 multifunctional measurement channels、2 detected thermocouple + current measurement channel |
|
multifunctional measurement channels’ function |
mA/mV/V/Ω(2、3、4wires)measurement,DC24Voutput,HART transmitter(*),switch measurement, etc | mA/mV/V/Ω(2、3、4wires)/RTD/TC measurement,DC24V output,HART transmitter(*),switch measurement, etc | |
Standard TC channel’s parameter |
TC types:S、R、B,Measurement range:-18~18mV,temp measurement accuracy :±(0.005%rdg + 2uV),temp coefficient:5PPM.FS/℃ | TC types:S、R、B,Measurement range:-18~18mV, measurement accuracy :±(0.005%rdg + 2uV),temp coefficient:5PPM.FS/℃ | |
Standard RTD channel’s parameter |
Measurement types: 4 -wires RTD constant current commutator true ohm measurement ; RTD types: ITS-90、CVD、IEC-751; Resistance measurement range :(0~400)Ω;accuracy :±0.002Ω @(0~50)Ω,±40ppm reading @(50~400)Ω;resolution rate:1mΩ;temperature coefficient:±1ppmreadking/℃(0~8℃ or 38~50℃) ; | Measurement types: 4 -wires RTD constant current commutator true ohm measurement ; RTD types: ITS-90、CVD、IEC-751;Resistance measurement range :(0~400)Ω;accuracy :±0.002Ω @(0~50)Ω,±40ppm reading @(50~400)Ω;resolution rate:1mΩ;temperature coefficient:±1ppm reading/℃(0~8℃ or 38~50℃) ; | |
built-in cold junction index |
Measurement range:0~50℃,accuracy :±0.2℃,sensor type :PT100 | Measurement range:0~50℃,accuracy :±0.2℃,sensor type :PT100 | |
Detected channel mV/TC index |
TC type:MINI-TC interface,S/R/K/B/N/E/J/T/C/D/G/L/U,total 13 types;signal range:(-75~75)mV;accuracy :±(0.01%rdg + 8uV);resolution rate:1µV;temperature coefficient :±5ppm reading/℃ (0℃~8℃ or 38℃~50℃);Cold junction measurement range and acuracy :±0.35℃ @(0~50)℃; | TC type:MINI-TC interface,S/R/K/B/N/E/J/T/C/D/G/L/U,total 13 types;signal range:(-75~75)mV;accuracy :±(0.01%rdg + 8uV);resolution rate:1µV;temperature coefficient :±5ppm reading/℃ (0℃~8℃ or 38℃~50℃);Cold junction measurement range and accuracy :±0.35℃ @(0~50)℃; | |
Detected channel Ω/RTD index |
Measurement types:2 wires /3 wires/4 wires RTD constant current commutator true ohm measurement ;RTD types:PT10、PT25、PT50、PT100、PT200、PT500、PT1000、CU10、CU50、CU100、NI100、NI120,etc;Resistance measurement range:(0~400)Ω、(0~4000)Ω;accuracy :±0.002Ω @(0~25)Ω,±80ppm reading @(25~4000)Ω;2 wires measurement adds 50 mΩ;measurement resolution rate:1mΩ(400Ω), 10mΩ(4000Ω); temperature coefficient :±1ppm reading/℃(0~8℃ or 38~50℃) ; |
Measurement types:2 wires /3 wires/4 wires RTD constant current commutator true ohm measurement ;RTD types:PT10、PT25、PT50、PT100、PT200、PT500、PT1000、CU10、CU50、CU100、NI100、NI120,etc;Resistance measurement range:(0~400)Ω、(0~4000)Ω;accuracy :±0.002Ω @(0~25)Ω,±80ppm reading @(25~4000)Ω;2 wires measurement adds 50 mΩ;measurement resolution rate:1mΩ(400Ω), 10mΩ(4000Ω); temperature coefficient :±1ppm reading/℃(0~8℃ or 38~50℃) ; |
|
Detected channel mA index |
Measurement range:-30~30mA,measurement accuracy:±(0.01%rdg + 2uA), input impedance :<10Ω,temperature coefficient :5ppm.FS/℃ | Measurement range:-30~30mA,measurement accuracy:±(0.01%rdg + 2uA), input impedance :<10Ω,temperature coefficient :5ppm.FS/℃ | |
Detected channel V index |
Measurement range:-30~30V、-12~12V(auto range),measurement accuracy:±(0.01%rdg + 0.6mV),input impedance:>1MΩ,temperature coefficient:5ppm.FS/℃ | Measurement range:-30~30V、-12~12V(auto range),measurement accuracy:±(0.01%rdg + 0.6mV),input impedance:>1MΩ,temperature coefficient:5ppm.FS/℃ | |
Detected channel-other index |
Supports mechanical and electronic switches ;temperature transmitter: support current、voltage and HART transmitter(*);Loop power :DC24V±0.5V,max load current 60mA |
temperature switch:Supports mechanical and electronic switches;temperature transmitter: support current、voltage and HART transmitter(*);Loop power :DC24V±0.5V,max load current 60mA | |
Working temperature range(ensure its index ) |
23±5℃ |
23±5℃ |
Product detail pictures:
Related Product Guide:
We are also specializing in improving the things management and QC method in order that we could retain terrific edge inside the fiercely-competitive small business for China Cheap price Dry Block Calibration Furnace - ET3805 Intelligent Dry Block Temperature Calibrator Used In Laboratory – Zhongchuang , The product will supply to all over the world, such as: belarus, Moscow, Cyprus, We aspire to meet the demands of our customers globally. Our range of products and services is continuously expanding to meet customers' requirements. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
By Georgia from Turkey - 2017.08.18 18:38
Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
By Constance from Kuala Lumpur - 2017.08.21 14:13