ET1090/ET1091 Benchtop LCR Meter for Component Measurement
¤ The highest measuring frequency is 100kHz, and the stepping; frequency is continuously adjustable at 1Hz;
¤ Test level 10~2000 mV, 1 mV step continuously adjustable;
¤ Supporting DC Resistance (DCR) and Electrolytic Capacitance Measurement;
¤ Internal bias voltage output 10mV~1500mV;
¤ 3.5-inch TFT display, 5-bit display;
¤ Data recording function (maximum, minimum, average);
¤ Supporting SCPI Communication Protocol;
¤ Provide system settings to configure Chinese or English, buzzer, screen brightness, etc;
¤ The basic measurement accuracy is 0.2%;
¤ Manual and automatic range;
¤ With open circuit and short circuit calibration function;
¤ Comparator sorting (5 gears), alarm function.
Model |
ET1090A |
ET1090B |
ET1090C |
ET1091A |
ET1091B |
ET1091C |
Testing frequency |
10 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K) |
12 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K) |
16 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K, 40K, 50K, 80K, 100K) |
10-10KHz continuous adjustable, 1Hz stepby-step |
10-10KHz continuous adjustable, 1Hz stepby-step |
10-100KHz continuous adjustable, 1Hz step by-step |
Display screen |
Display screen 3.5 inch TFT LCD |
|||||
Number of display digits |
Principal parameter: 5 digit,Secondary parameter: 5 digit |
|||||
Measured parameter |
Principal parameter: L/C/R/Z,Secondary parameter: X/D/Q/θ/ESR |
|||||
Measurement Range |
L:0.001μH~9999H |
|||||
C:0.001pF~99.999mF |
||||||
R:0.0001Ω~99.99MΩ |
||||||
Basic accuracy |
0.20% |
|||||
Measuring display speed |
2 time/s (slow), 4 times/s (medium), 8 time/s (fast) |
|||||
Internal bias |
0-1500mV adjustable, at a step of 1mV. |
|||||
Testing level |
Six fixed level(0.1V、0.3V、0.6V、1V、1.5V、2V) |
0.1~2V adjustable, at a step of 1mV. |
||||
Signal source output impedance |
30Ω、100Ω |
|||||
Calibration function |
Open circuit calibration, short circuit calibration |
|||||
Screening function |
The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%. |
|||||
Comparator |
5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting |
|||||
Interfaces |
standard: RS232(or 485), USB Device, Handler ;optional: GPIB,USB Host |
|||||
Others |
Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional |
¤ Power supply voltage: 220V.AC±10%, or 110V.AC±10%, 45~65Hz;
¤ Power consumption: <10W;
¤ Display: 3.5 inch TFT LCD screen, resolution 480 *320, color 16M;
¤ Temperature range: Operating state 10℃~+40℃, non-operating state -10℃ ~+60℃;
¤ Humidity range: 0 ~ 40 C, < 90% relative humidity;
¤ Interface: RS232 (or 485), USB Device, Handle, GPIB, USB Host.
¤ Three core power cord(30A51)
¤ 4-terminals of kelvin testing cable(35A51)