ET1092 Series Benchtop High Frequency LCRMeter, LCR Bridge
¤ 0.05% basic accuracy.
¤ Measuring speed up to 200 times per second.
¤ 10Hz-1MHz Frequency Measurement Range, Continuous Adjustable, 1mHz Step.
¤ Test signal level 10 mV-2 V adjustable, 1 mV step-by-step.
¤ Internal Programmable DC Bias Voltage-2V~+2V.
¤ Supporting external DC bias voltage-60V~+60V.
¤ Supporting external current source.
¤ Automatic Level Adjustment of Voltage or Current.
¤ V, I and other test signal monitoring functions.
¤ 10-Point List Scanning Test Function.
¤ 10-grade sorting and counting function.
¤ 100 sets of self-calibration data.
¤ Automatic and manual range.
¤ 7 inch LCD display, Chinese and English interface.
¤ USB, LAN, RS232, GPIB, HANDLER interfaces.
¤ Passive components: capacitors, inductors, magnetic cores, resistors, piezoelectric devices, transformers, chip components and network components impedance parameter evaluation and performance analysis.
¤ Semiconductor components: C-VDC characteristics of varactor diodes; parasitic parameter analysis of transistors or integrated circuits.
¤ Other Components: Impedance Evaluation of Printed Circuit Board, Relay, Switch, Cable, Battery, etc.
¤ Dielectric materials: dielectric constant and loss angle of plastics, ceramics and other materials evaluation of magnetic materials: permeability and loss angle evaluation of ferrites, amorphous and other magnetic materials.
¤ Semiconductor Materials: Dielectric Constants, Conductivity and C-V Properties of Semiconductor Materials.
¤ Liquid Crystal Materials: C-V Characteristics of Dielectric Constants and Elastic Constants of Liquid Crystal Units.
¤ Electronic capacitors, substrates, PCB, antennas, ferrites, shock absorbers, SAR phantom materials.
¤ Aerospace/National Defense Stealth, RAM (Radar Wave Absorbing Material), Radome.
¤ Industrial Material Ceramics and Composites Automotive Parts and Coatings.
¤ Polymers and Plastic Fibers, Films, Insulating Materials.
¤ Hydrogel disposable diapers and soft contact lenses.
¤ Liquid crystal display.
¤ Other products containing such materials such as tyres, coatings, adhesives, etc.
¤ Study on Fresh Preservation (Deterioration) of Food and Agricultural Food, Microwave Food Development, Packaging and
Moisture Content Measurement.
¤ Water Content Measurement and Oil Content Analysis of Wood/Paper Products in Forestry and Mining Industry.
¤ Pharmaceutical and medical drug research and production, biological implants, human tissue characterization, biomass, fermentation.
Model |
ET1092E |
ET1092D |
ET1092C |
ET1092B |
ET1092A |
Test signal frequency range |
10Hz-1MHz |
10Hz-500kHz |
10Hz-300kHz |
10Hz-200kHz |
10Hz-100kHz |
Frequency Resolution and Accuracy |
Resolution 1 mHz, accuracy 0.01% |
||||
Test parameters |
Cp-D,Cp-Q,Cp-G,Cp-Rp,Cs-D,Cs-Q,Cs-Rs, Lp-D,Lp-Q,Lp-G,Lp-Rp,Ls-D,Ls-Q,Ls-Rs, Rs-Xs,|Z|-θr,|Z|-θd,|Y|-θr,|Y|-θd,G-B |
||||
Measuring display speed (> 100Hz) |
Fast 50 times per second (20ms), moderate 10 times per second (100ms), slow 1.25 times per second (800ms) |
||||
Customized measurement speed(> 1kHz) |
It can be set between 0.5 times per second and 200 times per second |
||||
LCR parameter display range |
Cp、Cs:0.001000pF~99.9999F Lp、Ls:0.001000nH~99.9999kH Rp、Rs、|Z|、Xs:0.001000mΩ~999.999MΩ G、B、|Y|:0.001000μS~999.999kS θr:±0.000001rad~3.14159rad θd:±0.000001deg~179.9999deg D:±0.000001~9.99999 Q:±0.001~99999.9 |
||||
Test signal voltage range |
0~2Vrms |
||||
Voltage Resolution and Accuracy |
Resolution 1 mV, accuracy 5%+5 mV |
||||
Test signal current range |
100μArms~20mArms |
||||
Current Resolution and Accuracy |
Resolution 10 μA, Accuracy 5%+50 μA |
||||
DC bias voltage source
|
Internal: - 2V ~+2V voltage bias, - 20mA ~+20mA current bias |
||||
External: - 60V ~+60V Voltage Bias |
|||||
Internal resistance of signal source |
30 ohms, 100 ohms optional |
||||
Basic accuracy |
0.05% |
||||
Display resolution |
6 1/2 digit |
||||
comparator |
8 combination, 1 unqualified and 1 subsidiary |
||||
Trigger mode |
Internal, manual, external, bus |
||||
Mathematical operations |
Delta (absolute value), Delta (percentage), direct reading |
||||
Calibration function |
Self-Calibration, Open Circuit, Short Circuit, Load, 100 Sets of Self-Setting Frequency Points |
||||
List scanning |
10-Point List Scanning Test |
||||
Storage device |
Internal /USB memory |
||||
Interface |
GPIB、LAN、RS232、USB Host、USB Device、Handler,(3501 GPIB is the choice) |
¤ Power voltage: 220V.AC ±10%, 50Hz,Optional 110V.AC ±10%, 50Hz;
¤ Power consumption: <20W;
¤ Display: 7” TFT LCD, with a resolution of 800*480;
¤ Interfaces: Ethernet, RS232, GPIB, USB and Handler interfaces;
¤ Service environment: 0°C-40°C;
¤ Sizes: 330mm*285mm*136mm (L*W*H);
¤ Weight: 3.6kg.
¤ GPIB Cable (32P01);
¤ Rs232 Serial Port Line (32P04);
¤ USB Data Line (32P05);
¤ 2m/4m test cable (35P01);
¤ SMD patch element test fixture (35P02);
¤ LCR test pen/four-wire patch element test clamp (35P03);
¤ Kelvin Test Clamp (35P04).
¤ Three core power cord(30P04);
¤ Kelvin test clip(35P04)