Factory Cheap Hot Scientific Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang
Factory Cheap Hot Scientific Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang Detail:
¤ The highest measuring frequency is 100kHz, and the stepping; frequency is continuously adjustable at 1Hz;
¤ Test level 10~2000 mV, 1 mV step continuously adjustable;
¤ Supporting DC Resistance (DCR) and Electrolytic Capacitance Measurement;
¤ Internal bias voltage output 10mV~1500mV;
¤ 3.5-inch TFT display, 5-bit display;
¤ Data recording function (maximum, minimum, average);
¤ Supporting SCPI Communication Protocol;
¤ Provide system settings to configure Chinese or English, buzzer, screen brightness, etc;
¤ The basic measurement accuracy is 0.2%;
¤ Manual and automatic range;
¤ With open circuit and short circuit calibration function;
¤ Comparator sorting (5 gears), alarm function.
Model |
ET1090A |
ET1090B |
ET1090C |
ET1091A |
ET1091B |
ET1091C |
Testing frequency |
10 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K) |
12 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K) |
16 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K, 40K, 50K, 80K, 100K) |
10-10KHz continuous adjustable, 1Hz stepby-step |
10-10KHz continuous adjustable, 1Hz stepby-step |
10-100KHz continuous adjustable, 1Hz step by-step |
Display screen |
Display screen 3.5 inch TFT LCD |
|||||
Number of display digits |
Principal parameter: 5 digit,Secondary parameter: 5 digit |
|||||
Measured parameter |
Principal parameter: L/C/R/Z,Secondary parameter: X/D/Q/θ/ESR |
|||||
Measurement Range |
L:0.001μH~9999H |
|||||
C:0.001pF~99.999mF |
||||||
R:0.0001Ω~99.99MΩ |
||||||
Basic accuracy |
0.20% |
|||||
Measuring display speed |
2 time/s (slow), 4 times/s (medium), 8 time/s (fast) |
|||||
Internal bias |
0-1500mV adjustable, at a step of 1mV. |
|||||
Testing level |
Six fixed level(0.1V、0.3V、0.6V、1V、1.5V、2V) |
0.1~2V adjustable, at a step of 1mV. |
||||
Signal source output impedance |
30Ω、100Ω |
|||||
Calibration function |
Open circuit calibration, short circuit calibration |
|||||
Screening function |
The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%. |
|||||
Comparator |
5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting |
|||||
Interfaces |
standard: RS232(or 485), USB Device, Handler ;optional: GPIB,USB Host |
|||||
Others |
Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional |
¤ Power supply voltage: 220V.AC±10%, or 110V.AC±10%, 45~65Hz;
¤ Power consumption: <10W;
¤ Display: 3.5 inch TFT LCD screen, resolution 480 *320, color 16M;
¤ Temperature range: Operating state 10℃~+40℃, non-operating state -10℃ ~+60℃;
¤ Humidity range: 0 ~ 40 C, < 90% relative humidity;
¤ Interface: RS232 (or 485), USB Device, Handle, GPIB, USB Host.
¤ Three core power cord(30A51)
¤ 4-terminals of kelvin testing cable(35A51)
Product detail pictures:
Related Product Guide:
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Factory Cheap Hot Scientific Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang , The product will supply to all over the world, such as: Islamabad, Johannesburg, Suriname, We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.
By Maxine from UK - 2018.12.30 10:21
Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
By Edith from New Orleans - 2018.10.09 19:07