Good Quality Lcr Meter - ET1092 Series Benchtop High Frequency LCRMeter, LCR Bridge – Zhongchuang
Good Quality Lcr Meter - ET1092 Series Benchtop High Frequency LCRMeter, LCR Bridge – Zhongchuang Detail:
¤ 0.05% basic accuracy.
¤ Measuring speed up to 200 times per second.
¤ 10Hz-1MHz Frequency Measurement Range, Continuous Adjustable, 1mHz Step.
¤ Test signal level 10 mV-2 V adjustable, 1 mV step-by-step.
¤ Internal Programmable DC Bias Voltage-2V~+2V.
¤ Supporting external DC bias voltage-60V~+60V.
¤ Supporting external current source.
¤ Automatic Level Adjustment of Voltage or Current.
¤ V, I and other test signal monitoring functions.
¤ 10-Point List Scanning Test Function.
¤ 10-grade sorting and counting function.
¤ 100 sets of self-calibration data.
¤ Automatic and manual range.
¤ 7 inch LCD display, Chinese and English interface.
¤ USB, LAN, RS232, GPIB, HANDLER interfaces.
¤ Passive components: capacitors, inductors, magnetic cores, resistors, piezoelectric devices, transformers, chip components and network components impedance parameter evaluation and performance analysis.
¤ Semiconductor components: C-VDC characteristics of varactor diodes; parasitic parameter analysis of transistors or integrated circuits.
¤ Other Components: Impedance Evaluation of Printed Circuit Board, Relay, Switch, Cable, Battery, etc.
¤ Dielectric materials: dielectric constant and loss angle of plastics, ceramics and other materials evaluation of magnetic materials: permeability and loss angle evaluation of ferrites, amorphous and other magnetic materials.
¤ Semiconductor Materials: Dielectric Constants, Conductivity and C-V Properties of Semiconductor Materials.
¤ Liquid Crystal Materials: C-V Characteristics of Dielectric Constants and Elastic Constants of Liquid Crystal Units.
¤ Electronic capacitors, substrates, PCB, antennas, ferrites, shock absorbers, SAR phantom materials.
¤ Aerospace/National Defense Stealth, RAM (Radar Wave Absorbing Material), Radome.
¤ Industrial Material Ceramics and Composites Automotive Parts and Coatings.
¤ Polymers and Plastic Fibers, Films, Insulating Materials.
¤ Hydrogel disposable diapers and soft contact lenses.
¤ Liquid crystal display.
¤ Other products containing such materials such as tyres, coatings, adhesives, etc.
¤ Study on Fresh Preservation (Deterioration) of Food and Agricultural Food, Microwave Food Development, Packaging and
Moisture Content Measurement.
¤ Water Content Measurement and Oil Content Analysis of Wood/Paper Products in Forestry and Mining Industry.
¤ Pharmaceutical and medical drug research and production, biological implants, human tissue characterization, biomass, fermentation.
Model |
ET1092E |
ET1092D |
ET1092C |
ET1092B |
ET1092A |
Test signal frequency range |
10Hz-1MHz |
10Hz-500kHz |
10Hz-300kHz |
10Hz-200kHz |
10Hz-100kHz |
Frequency Resolution and Accuracy |
Resolution 1 mHz, accuracy 0.01% |
||||
Test parameters |
Cp-D,Cp-Q,Cp-G,Cp-Rp,Cs-D,Cs-Q,Cs-Rs, Lp-D,Lp-Q,Lp-G,Lp-Rp,Ls-D,Ls-Q,Ls-Rs, Rs-Xs,|Z|-θr,|Z|-θd,|Y|-θr,|Y|-θd,G-B |
||||
Measuring display speed (> 100Hz) |
Fast 50 times per second (20ms), moderate 10 times per second (100ms), slow 1.25 times per second (800ms) |
||||
Customized measurement speed(> 1kHz) |
It can be set between 0.5 times per second and 200 times per second |
||||
LCR parameter display range |
Cp、Cs:0.001000pF~99.9999F Lp、Ls:0.001000nH~99.9999kH Rp、Rs、|Z|、Xs:0.001000mΩ~999.999MΩ G、B、|Y|:0.001000μS~999.999kS θr:±0.000001rad~3.14159rad θd:±0.000001deg~179.9999deg D:±0.000001~9.99999 Q:±0.001~99999.9 |
||||
Test signal voltage range |
0~2Vrms |
||||
Voltage Resolution and Accuracy |
Resolution 1 mV, accuracy 5%+5 mV |
||||
Test signal current range |
100μArms~20mArms |
||||
Current Resolution and Accuracy |
Resolution 10 μA, Accuracy 5%+50 μA |
||||
DC bias voltage source
|
Internal: – 2V ~+2V voltage bias, – 20mA ~+20mA current bias |
||||
External: – 60V ~+60V Voltage Bias |
|||||
Internal resistance of signal source |
30 ohms, 100 ohms optional |
||||
Basic accuracy |
0.05% |
||||
Display resolution |
6 1/2 digit |
||||
comparator |
8 combination, 1 unqualified and 1 subsidiary |
||||
Trigger mode |
Internal, manual, external, bus |
||||
Mathematical operations |
Delta (absolute value), Delta (percentage), direct reading |
||||
Calibration function |
Self-Calibration, Open Circuit, Short Circuit, Load, 100 Sets of Self-Setting Frequency Points |
||||
List scanning |
10-Point List Scanning Test |
||||
Storage device |
Internal /USB memory |
||||
Interface |
GPIB、LAN、RS232、USB Host、USB Device、Handler,(3501 GPIB is the choice) |
¤ Power voltage: 220V.AC ±10%, 50Hz,Optional 110V.AC ±10%, 50Hz;
¤ Power consumption: <20W;
¤ Display: 7” TFT LCD, with a resolution of 800*480;
¤ Interfaces: Ethernet, RS232, GPIB, USB and Handler interfaces;
¤ Service environment: 0°C-40°C;
¤ Sizes: 330mm*285mm*136mm (L*W*H);
¤ Weight: 3.6kg.
¤ GPIB Cable (32P01);
¤ Rs232 Serial Port Line (32P04);
¤ USB Data Line (32P05);
¤ 2m/4m test cable (35P01);
¤ SMD patch element test fixture (35P02);
¤ LCR test pen/four-wire patch element test clamp (35P03);
¤ Kelvin Test Clamp (35P04).
¤ Three core power cord(30P04);
¤ Kelvin test clip(35P04)
Product detail pictures:
Related Product Guide:
In the past few years, our company absorbed and digested advanced technologies both at home and abroad. Meanwhile, our company staffs a team of experts devoted to the development of Good Quality Lcr Meter - ET1092 Series Benchtop High Frequency LCRMeter, LCR Bridge – Zhongchuang , The product will supply to all over the world, such as: Ireland, Bangladesh, Zambia, Certainly, competitive price, suitable package and timely delivery will be assured as per customers' demands. We sincerely hope to build business relationship with you on the basis of mutual benefit and profit in the very near future. Warmly welcome to contact us and become our direct cooperators.