Being supported by an state-of-the-art and skilled IT team, we could supply technical support on pre-sales & after-sales service for Lcr Meter Inductance, Thermostatic Bath, Programmable Ac Electronic Load, We can give you the most competitive prices and high quality, because we are much more PROFESSIONAL! So please do not hesitate to contact us.
OEM/ODM China High Frequency Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang Detail:

¤ The highest measuring frequency is 100kHz, and the stepping; frequency is continuously adjustable at 1Hz;

¤ Test level 10~2000 mV, 1 mV step continuously adjustable;

¤ Supporting DC Resistance (DCR) and Electrolytic Capacitance Measurement;

¤ Internal bias voltage output 10mV~1500mV;

¤ 3.5-inch TFT display, 5-bit display;

¤ Data recording function (maximum, minimum, average);

¤ Supporting SCPI Communication Protocol;

¤ Provide system settings to configure Chinese or English, buzzer, screen brightness, etc;

¤ The basic measurement accuracy is 0.2%;

¤ Manual and automatic range;

¤ With open circuit and short circuit calibration function;

¤ Comparator sorting (5 gears), alarm function. 

Model

ET1090A

ET1090B

ET1090C

ET1091A

ET1091B

ET1091C

Testing frequency

10 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K)

12 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K)

16 points (100, 120, 200, 400, 800, 1K, 2K, 4K, 8K, 10K, 15K, 20K, 40K, 50K, 80K, 100K)

10-10KHz continuous adjustable, 1Hz stepby-step

10-10KHz

continuous

adjustable, 1Hz stepby-step

10-100KHz

continuous

adjustable, 1Hz step by-step

Display screen

Display screen 3.5 inch TFT LCD

Number of display digits

Principal parameter: 5 digit,Secondary parameter: 5 digit

Measured parameter

Principal parameter: L/C/R/Z,Secondary parameter: X/D/Q/θ/ESR

Measurement Range

L:0.001μH~9999H

C:0.001pF~99.999mF

R:0.0001Ω~99.99MΩ

Basic accuracy

0.20%

Measuring display speed

2 time/s (slow), 4 times/s (medium), 8 time/s (fast)

Internal bias

0-1500mV adjustable, at a step of 1mV.

Testing level

Six fixed level(0.1V、0.3V、0.6V、1V、1.5V、2V)

0.1~2V adjustable, at a step of 1mV.

Signal source output

impedance

30Ω、100Ω

Calibration function

Open circuit calibration, short circuit calibration

Screening function

The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%.

Comparator

5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting

Interfaces

standard: RS232(or 485), USB Device, Handler ;optional: GPIB,USB Host

Others

Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional

¤ Power supply voltage: 220V.AC±10%, or 110V.AC±10%, 45~65Hz;

¤ Power consumption: <10W;

¤ Display: 3.5 inch TFT LCD screen, resolution 480 *320, color 16M;

¤ Temperature range: Operating state 10℃~+40℃, non-operating state -10℃ ~+60℃;

¤ Humidity range: 0 ~ 40 C, < 90% relative humidity;

¤ Interface: RS232 (or 485), USB Device, Handle, GPIB, USB Host. 

¤ Three core power cord(30A51)

¤ 4-terminals of kelvin testing cable(35A51) 

ET1090ET1091 Benchtop LCR Meter for Component Measurement 1
ET1090ET1091 Benchtop LCR Meter for Component Measurement 2
ET1090ET1091 Benchtop LCR Meter for Component Measurement 3
ET1090ET1091 Benchtop LCR Meter for Component Measurement 4


Product detail pictures:

OEM/ODM China High Frequency Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures

OEM/ODM China High Frequency Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures

OEM/ODM China High Frequency Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures

OEM/ODM China High Frequency Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang detail pictures


Related Product Guide:

Good quality comes to start with; service is foremost; organization is cooperation" is our enterprise philosophy which is regularly observed and pursued by our firm for OEM/ODM China High Frequency Lcr Meter - ET1090/ET1091 Benchtop LCR Meter for Component Measurement – Zhongchuang , The product will supply to all over the world, such as: Azerbaijan, Japan, Mali, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Astrid from moldova - 2018.11.11 19:52
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Ivy from Benin - 2017.08.16 13:39
    Write your message here and send it to us