Professional China Forehead Thermometer Infrared Calibrator - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang
Professional China Forehead Thermometer Infrared Calibrator - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang Detail:
¤ Measurement/output: voltage, current, resistance, frequency, pulse, switching values, in which the current output supports active and passive;
¤ 220V measurement function
¤ 200mA AC current measurement function
¤ Simulating RTD and thermocouple through temperature form
¤ Simulating 2-wire transmitter
¤ Resistance measurement options: 2 wires, 3 wires, 4 wires
¤ Accuracy: 0.01%, 0.02%
¤ Two isolated channels support measure and output simultaneously
¤ Providing manual step, automatic step, automatic step and manual step functions.
¤ 3.5 TFT LCD screen,resolution rate 480*320
¤ Measurement and output data can be displayed simultaneously or separately;
¤ 5000mAh Lithium battery
¤ Automatic power shutdown function, shutdown time can be set, and suitable for on-site use
¤ DC 24V loop power for on -site use
¤ Thermocouple measurement and output provide three kinds of cold junction temperature compensation methods: built-in, external and manual, among them, external reference junction adopts A class Pt100 Platinum resistance, which can correct temperature through inputting certificate value
¤ Thermocouple types: R,S,K,E,J,T,N,B,L,U,XK,WRE325,WRE526;
¤ RTD
types:PT100-385,PT100-392,PT100-JIS,PT200-385,PT500-385,PT1000-385,Cu10,Cu50,Cu100,Nil20,BA1,BA2,PT10;
¤ HART Function:completely replace HART communicator;set or calibrate smart transmitter’s range; force the output current of intelligent transmitter at fix value(20mA, 12mA, 4mA ) set linear or square function; Set up linear or square functions, which can HART reset the pressure sensor of transmitter, etc.;
¤ Pressure module function: through RS232 communication port, it can be used together with our COMPANY’s ET-CY series pressure module, for on-site verification of pressure transmitter, pressure switch, pressure gauge, blood pressure meter or other pressure instruments, and also for precise measurement of pressure;Support 12 pressure units: kPa, MPa, Pa, PSI, inHg, inH2O, mmHg, mmH2O, bar, Mbar, ATM, kg/cm2, etc.
¤ Temperature difference measurement function: the accuracy is up to 0.003℃. This product can measure the temperature difference between two points in the space, and complete a temperature difference data collection within 0.4 seconds, effectively improving the measurement accuracy.The 10-minute fluctuation during the test can be calculated in real time.Before using standard platinum resistance or standard thermocouple for measuring work, the measurement results can be traced through the input of certificate value, and meet the requirements of the thermostatic tank test specification for electrical measuring instruments.
¤ Standard temperature measurement function: Comparing with common thermocouple measurement and RTD measurement,the difference is that this measurement method can trace the temperature by certificate value,the supported standard thremocouple and RTD are as followed: S、R、B、T,Pt25、Pt100
¤ Arbitrary sensor’s measurement function; Users can transform the measured physical quantity(Pressure, flow speed, temperature,etc) to voltage, current, resistance,etc conveniently for measurement. Besides, Users only need to input the response curve in advance, and the multimeter will adopt the internal algorithm for numerical conversion and correction, and finally the measured physical quantity will be displayed on the screen.You are free to edit and modify the display units of the measured physical quantities.
¤ Precision temperature control function; Precision temperature control function will realize the temperature closed-loop control of thermostatic equipment, which replace the high precision PID controller.Under the condition of thermostatic equipment and network voltage,temperature fluctuation will be better than 0.02℃/10min (Thermostatic Bath)
Measurement function of ρ’s value: can measure duty ratio of periodic square wave signal; verify and calibrate the PID parameter of Various digital temperature indicating regulators which is outputted by time scale
¤ Thermal Conversion Function: realize the conversion between various electric quantity and temperature.The types of electric quantity and temperature conversion include: working thermocouple, industrial rtd and various temperature transmitter.
¤ Numerical setting mode:its with the most flexible and convenient way to set output value; User can use the numerical keyboard to set output value directly, and can realize the incremental setting by direction key.In addition, the equipment also has a step or ramp numerical setting mode that can be numbered.
¤ Sinusoidal output function: The verification/calibration of some process logger (especially mechanical logger); Usually It involves running test, and it can provide signals to the measured table by using sinusoidal output mode.
¤ Data Record Function: with powerful record management function, it can establish up to 32 device numbers. Each device number has 16 record pages, and each record page contains four basic information: time, measured value, output value and custom value.Users can carry out equipment management, record deletion and other operations according to requirements.
Model |
Accuracy |
Temp Range |
Optional function |
ET2125B |
0.01% |
15~25℃ |
For optional function,please contact us for detail code information about its relevant function |
ET2125C |
0.02% |
||
ET2125BT |
0.01% |
0~50℃ |
|
ET2125CT |
0.02% |
Function |
Range |
Resolution rate(0.01%) |
Resolution rate(0.02%) |
Accuracy(0.01%) |
Accuracy(0.02%) |
Note |
|
DC Output |
Voltage |
100mV |
0.1µV |
1µV |
0.005%+0.003% |
0.01%+0.005% |
Max load current <=2.5mA |
1V |
1µV |
10µV |
0.005%+0.001% |
0.01%+0.005% |
|||
10V |
10µV |
100µV |
0.005%+0.001% |
0.01%+0.005% |
|||
Current (Active/Passive) |
30mA |
0.1µA |
1µA |
0.005%+0.003% |
0.01%+0.003% |
Max load voltage(active output)20V | |
Resistance |
50Ω |
0.1mΩ |
0.005%+10 mΩ |
0.01%+15 mΩ |
Excitation current 0.4-4mA | ||
500Ω |
1mΩ |
0.005%+20 mΩ |
0.01%+30 mΩ |
Excitation current 0.1-2mA | |||
5000Ω |
10mΩ |
0.005%+50 mΩ |
0.01%+50 mΩ |
Excitation current 0.04-0.4mA | |||
24V |
24V |
|
±10% |
Loop output | |||
Frequency |
10Hz |
0.001Hz |
0.01%FS |
Max load current ≤2.5mA | |||
1kHz |
0.01Hz |
||||||
100kHz |
10Hz |
||||||
|
10Hz(1~100000) |
1cyc |
±2dig |
Max load current ≤2.5mA | |||
1kHz(1~100000) |
|||||||
100kHz(1~100000) |
|||||||
Switch value |
100Hz(1Hz~110Hz) |
0.01Hz |
±2dig |
||||
1kHz(0.1kHz~1.1kHz) |
1Hz |
||||||
10kHz(1kHz~11kHz) |
0.1KHz |
||||||
100KHz(10kHz~110kHz) |
2KHz |
||||||
RTD |
See detail of RTD sheet |
||||||
Thermocouple |
See detail of thermocouple sheet |
||||||
DC Measurement |
Voltage |
200mV |
0.1µV |
0.005%+0.003% |
0.01%+0.005% |
|
|
2V |
1µV |
0.005%+0.001% |
0.01%+0.005% |
|
|||
20V |
10µV |
0.005%+0.001% |
0.01%+0.005% |
|
|||
200V |
100µV |
0.005%+0.001% |
0.01%+0.005% |
|
|||
Current |
20mA |
0.1µA |
0.005%+0.003% |
0.01%+0.003% |
|
||
200mA |
1µA |
0.005%+0.003% |
0.01%+0.003% |
|
|||
Resistance (4-wire) |
50Ω |
0.1mΩ |
0.005%+10 mΩ |
0.01%+15 mΩ |
Excitation current 1mA |
||
500Ω |
1mΩ |
0.005%+20 mΩ |
0.01%+30 mΩ |
||||
5kΩ |
10mΩ |
0.005%+50 mΩ |
0.01%+50 mΩ |
Excitation current 0.1mA |
|||
Resistance (2,3-wire) |
50Ω |
0.1mΩ |
0.005%+30 mΩ (3-wire) 0.005%+50 mΩ (2-wire) |
0.005%+35 mΩ (3-wire) 0.005%+60 mΩ (2-wire) |
Excitation current 1mA |
||
500Ω |
1mΩ |
||||||
5kΩ |
10mΩ |
0.005%+80mΩ |
0.01%+80 mΩ |
Excitation current 0.1mA |
|||
RTD |
See detail of RTD sheet |
|
|||||
Thermocouple |
See detail of thermocouple sheet |
|
|||||
Switch measurement |
|
|
CLOSE/OPEN |
Excitation current 1mA |
|||
Frequency |
10Hz |
0.001Hz |
0.01%FS |
|
|||
1kHz |
0.01Hz |
|
|||||
100kHz |
10Hz |
|
|||||
AC Measurement |
AC Voltage |
200mV |
1µV |
±(0.2%+100)(40Hz-30kHz) |
|
||
2V |
10µV |
|
|||||
20V |
100µV |
±(0.2%+100)(40Hz-5kHz) ±(0.8%+300)(5k-30kHz) |
|
||||
200V |
1mV |
±(0.2%+200)(40Hz-5kHz) ±(0.8%+450)(5k-30kHz) |
|
||||
AC Current |
20mA |
0.1µA |
±(0.3%+400)(40Hz-5kHz) |
|
|||
200mA |
1µA |
Product detail pictures:
Related Product Guide:
While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for Professional China Forehead Thermometer Infrared Calibrator - ET2125 High-Precision Multifunctional Process Calibrator – Zhongchuang , The product will supply to all over the world, such as: Luxembourg, Belgium, Panama, With the development and enlargement of mass clients abroad, now we've set up cooperative relationships with many major brands. We've our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost items and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.
By Darlene from Zurich - 2017.05.21 12:31
This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
By Arlene from Swansea - 2018.09.19 18:37